Temperature Meters
|
C-306 Dual Input, Triple Display,
Data Logger
|
|
 |
 |
 |
- Dual inputs
- Triple display
- Type-K thermocouples
- -200 to +1,370°C measurement range
- 0.1°C/0.1°F resolution
- 60 VDC/24 VACrms input protection
- Auto power off
- 16,000 data record data logging
- TIME/HOLD/MAX/ MIN functions
- RS232 interface
- Includes battery, manual, two
Type-K bead sensors, RS232 cable and ThermoLog data
logging/analysis software (Windows)
|
 |
|
|
C-307 Mini Thermometer
|
|
 |
 |
 |
- Single input
- Type-K thermocouples
- -200 to +1,370°C measurement range
- 0.1°C/0.1°F resolution
- Autoranging
- 60 VDC/24 VACrms input protection
- Auto power off
- REL/HOLD/MAX/MIN functions
- resolution 0.1°C/0.1°F
|
 |
|
|
 |
C-308
Mini Dual Input, Dual Display
|
|
 |
 |
 |
- Dual input
- Dual displayType-K thermocouples
- -200 to +1,370°C measurement range
- 0.1°C/0.1°F resolution
- Autoranging
- 60 VDC/24 VACrms input protection
- Auto power off
- REL/HOLD/MAX/MIN functions
- Resolution 0.1°C/0.1°F
|
 |
|
|
C-358
LED Infrared Thermometer
|
|
 |
 |
 |
- Infrared LED thermometer
- -18 °C to +315 °C/0 °F to 600 °F
measurement range
- 0.5 °C/1 °F resolution
- °C/°F select switch
- Auto power off
- Display HOLD function
- Includes: battery and manual
|
 |
|
|
 |
C-500 Temperature Graphing
Recorder
 |
 |
 |
- Dual input
- Type-J; -200 to +760 °C, ±0.1% of
reading +0.8°C*
- Type-K; -200 to +1,370 °C, ±0.1%
of reading +0.8°C**
- Resolution 0.1°C/0.1°f
- Dual 5-digit display
- 10 character text display area
- Built-in thermal printer for
graphic and text printout
- Easy text menu setup
- Realtime clock
- 32,000 record data logging
- Opto-isolated RS232 interface with
Windows data logging software
- Includes: batteries, carrying
case, manual, 9V adapter, thermal paper, RS232 cable, data
logger software for Windows, K-Type bead sensor (TP-K01)
- *-328 to +1,400°F, ±0.1% of
reading +1.6°F
- **-328 to +2,498°F, ±0.1% of
reading +1.6°F
|
 |
|
|
LTC-920
Economy Series Thermocouple
Calibrator
|
|
 |
 |
 |
- Two-in-one meter ? Type K
thermometer & Type K thermocouple calibrator
- Wide range: -199 to +1230 °C (-325
to +2246 °F)
- Built-in, high precision,
temperature linearity compensation circuit
- °C & °F select & data hold
functions for temperature measurement.
- °C & °F button selection for
temperature calibration
- Temperature measuring input to
meet any standard Type K (NiCr-NiAl) probe
- Fitted with standard Type K
mini-plug socket
- Large LCD display
- Operates on 006P DC 9V battery
- RS232 PC serial computer interface
- Uses durable, long-lasting
components, including strong, light
- weight ABS-plastic housing
|
 |
 |
|
 |
LTM-917
Economy Series Precision
Thermometer
 |
 |
 |
- Precision thermometer with high
accuracy and 0.01°C resolution
- Accepts Platinum Pt-100 Ohm and
thermocouple Type K/J/T/E/R probes
- 0.01 degree high resolution both
for Platinum & Thermocouple probe input
- Pt-100 probe input compatible with
an 0.00385 alpha coefficient, and meets DIN IEC 751
- Compatible with 4-wire Pt-100 Ohm
probe
- -100 °C to 1370 °C (Type K)
display range
- Built-in front panel °C & °F
select button and 0.01/0.1 degree select switch
- Large LCD with unit display
- Data hold function for storing
displayed value
- Front panel Sensor Select button
provides easy probe change
- Memory function to record the
maximum & minimum reading with recall
- Built-in REL button for relative
measurement
- Built-in low battery indicator
- Optional RTD Probe - LTP-100
Temperature Probe
|
 |
 |
|
LTM-939
IR
Thermometer
|
|
 |
 |
 |
- 51 mm x 32 mm large LCD Display,
15 mm (0.6") digit size
- 2 in 1, Infrared Thermometer +
Thermocouple (Type K/J/T/E/R) thermometer
- Infrared thermometer (Non-contact
temperature measurement) - 20°C to 650°C (-4°F to 1112°F)
- °C, °F Data hold, Memory (Max.,
Min) Relative measurement, Emissivity adjustment (IR
thermometer)
- 0.1 degree or 1 degree Resolution
- Exclusive microcomputer circuit,
software built in linearity correction function instead of
the traditional hardware circuit
- Emissivity Adjustment Range of
0.20 to 1.00, button on front panel for adjustment
- Red laser light, less than 1 mW,
Meet EN60825
- Standard 2 pin thermocouple socket
- Approximately 1 second of sampling
time
- Hold function to freeze the
display reading value
- Memory function to record the
maximum & minimum reading
- Offset Adjustment available for IR
Thermometer, & Thermocouple Thermometer Adjustment
available by pushing button on front panel
- Over Indication: Show "- - - -"
- Data Output RS-232 PC serial
interface
- Alkaline or heavy duty type power
supply DC 9V battery, 006P, MN 1604 (PP3) or equivalent
- Approximately DC 11 mA power
consumption with laser light off
Approximately DC 16 mA power consumption with laser light
on
- Auto Power Off
- Low Battery Indicator
- 0°C to 50°C temperature (32°F to
122°F)
- Less than 80% RH Operating
Humidity
- HWD 200 x 68 x 30 mm in size, (7.9
x 2.7 x 1.2 inches)
- Weighs 220 g / 0.48 lb
- Includes: manual
- Options: Carrying Case, RS232
cable, Application Software, Windows version
|
 |
|
|
 |
|
|
|
|
|
|